pioneer mini split installation

Posted: 12th February 2021 by in Uncategorized

Using the proper mini split communication wire is critical to a properly functioning unit. The question is what and who is Pioneer? There was some narrow shelving under our unit we initially were going to remove later on, but after we tested the air flow and temperatures, we decided to keep them after all. I let it set for several hours. Basically, the indoor unit, outdoor unit, and a box of accessories. Did you have to flare the copper tubing before making the connections? I will be walking you through my installation of a Pioneer Ductless Mini Split. 2. It took me 3-4 hours to install everything. We used a Bosch hammer drill for the holes, then secured the outdoor unit using 4″ long hammer drive anchors. PIONEER Air Conditioner Ductless Mini Split System Charging Vacuum Port Adapter, Converts New R410a Style 5/16 SAE Service Ports to Accept Older 1/4 SAE Gauge Hoses. Signup for our newsletter to get notified about new, useful content for you. On the disconnect box outside, we connected the other ends of the black and white cables, grounded with the green cable, and tested the voltage to make sure it’s 120V each and 240V together here as well. Puron or reon? Wire gauge can be larger but not smaller. Pioneer RYB048GMFILCBD Ceiling Concealed Ducted Mini-Split Air Conditioner and Heat Pump System Full Set 4.4 out of 5 stars 32 Pioneer Air Conditioner CYB036GMFILCBD 8-Way Slim Cassette Mini-Split … At Pioneer Mini Split, digitally frequency controlled variable capacity ductless wall mount mini split systems are available with different efficiency ratings and in a variety of capacities for simple installation and great single-zone comfort. Glad you asked. Or is there another step that I’m missing. I could have used 12 Gauge wire but had the larger 10 gauge from another project so used it. If so, how do I do that, where do I do that, and how much do I put in? So we just went with the 24,000 BTU unit to be safe. Ideal-Air 728184 2 x 16 x 36 Cement Equipment Pad, Mini split heating and cooling air conditioner heat pump systems, Our Picks for the Best Tri Zone Mini Split Systems, https://removeandreplace.com/2017/06/19/pioneer-air-conditioner-mini-split-error-codes-and-troubleshooting-guide/, https://www.youtube.com/watch?v=Dg-w2uAsEJE. Yes, after evacuating the system, turn off the pump and close the valve on the manifold. Once everything is installed the line set will need to be vacuumed out with a Vacuum pump. Within 2 business days it was delivered to a nearby city, and we were texted a number to call to set up a freight delivery appointment. Units larger than that have the 208/230V voltage only. Update: 3 months later (in July), when we had 95°F weather, the unit was still cooling just as fine and there was no need for added refrigerant. Priority Home and Design LLC is compensated for referring traffic and business to these companies. Pioneer® single zone mini split systems are available in various capacities and designs to control the environmental conditions for residential and light commercial applications. But overall, it was worth it and this project only took an afternoon to do. One, a shorter pipe makes the unit more efficient and bend less. At first glance, the A/C was cooling fine since it already came charged with refrigerant, but we proceeded to do a test for pressure and leaks. Let the vacuum pump run for 15-20 minutes pulling a vacuum. This is done by removing the caps and using an Allen key turning them to the left counter-clockwise. Can One Dehumidifier Cover Multiple Rooms? Are they a reputable brand? Once our unit (WYS024) arrived, it stated on its side panel that our minimum circuit ampacity was 20A, while the max fuse/breaker was listed at 30A. Did you bend the copper tubing by hand or did you use a tool for this? give them a call if you have any questions. Cool setting at 69°F, highest auto fan setting: Heat setting at 82°F, highest auto fan setting: Now that our unit seemed to work just fine, it was time to put a decorative cover on the piping coming out the exterior wall. The standard way of quantifying a noise level is with a decibel or dB(A) measurement. The smaller units (12,000 BTU and below), you’ll be able to choose between 110/120V or 208/230V. We had a portable A/C in there (rated at 14,000 BTU), thinking that it would help at least somewhat if we ducted it correctly. The gauge will show negative pressure, after sitting for 20-30 minutes if it goes back up to 0 there is a leak and it needs to be fixed. This process varies by mini split model, but it typically … Ductless Split … They come with most everything needed except tools and electrical wiring to a panel. Both the high and low side will need to be released. I installed a 12000 BTU unit and it has been working very well.   Angle the saw downward slightly for better drainage. If you install a unit let us know how it goes. HVAC Load - Energy Savings - Multi-Split … Do not work with live electric wires or refrigerant if not qualified to do so. It’s important to double check you did this – once the flare is done, you won’t be able to put it on. We have a team of true pioneers and artisans of the PCB industry, as we build the flex and rigid flex cables that no one else can. The remote actually isn’t doing anything. A convenient remote controller conveys cooling, heating, dehumidification, and ventilation requests to the wall mount mini split … The valve to the vacuum pump is shut off on the gauges and refrigerant opened letting it into the system. Also when you boil the system down, or vacuum it down (water will boil under vacuum and be extracted from the system) vac it down, mark it on the gauge with tape, and leave it overnight. But, you’d be wise to wait for your unit to arrive before you go buy any breakers. DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP 9,000 BTU/h. We first released the nitrogen out of the green valve, then connected the two parts of the plastic drain hose. Use a hole saw bit to drill the 2-inch or 3-inch hole. There are many low-cost vacuum pumps and gauges which I bought some budget ones for the install. After putting back all covers, it was time to test the unit. I am going to be installing the 9k BTU 120v today, Here is a video I did installing a Senville Mini Split which I showed the steps better. https://www.youtube.com/watch?v=Dg-w2uAsEJE. I should have used the low side but was only testing for a vacuum and leaks. I have a 9000 BTU Pioneer WYS Series unit and would like to know if I need to bolt down the outdoor compressor to my concrete pad or just let the unit sit on the pad? You buy a can or tank of the refrigerant and using the gauge set you add more into the system. Anyhow i was looking up the wiring and breaker requirements for both units it says 15amp max breaker Otherwise start looking for your leak. then take the gauges off and release the rest. We’ll be taking down the disappointing portable A/C we had in the garage before this mini split very soon. Hi there, Once the refrigerant is in the system, power on the unit and it is ready to be tested. Again follow the schematic that comes with the unit. The refrigerant is in the outdoor unit that everything needs to be sealed before opening the valves. There is a plastic protector that slides into the hole and protects the wiring and copper lines if needed. Since our tubes were 3/8″ and 5/8″, each went into the corresponding slot in the flaring tool. The wires, line set, and drain line all need to be fed out the 3-inch hole and the unit mounted on the wall bracket. Tech at Pioneer said that I didn’t need to worry if I shortened the 16′. For starters, thank you for making such an easy to follow video. Here is a link to the Pioneer troubleshooting guide with error codes. Pipe cutter (we used the Ridgid shown here); ours, clearly a decade old: Flaring tool (we bought the Husky shown here from the Home Depot): After cutting the pipe, we inserted the brass nut. ... DAIKIN 12,000 BTU 19 SEER Wall-Mounted Ductless Mini-Split A/C Heat Pump System Maxwell 25-ft Installation … Pioneer is one such popular DIY Mini Split manufacture with several different sized units. Here is the unit I bought on Amazon There are many units available from small 9000 BTU units to large 36000 BTU units. We drilled through the inside wall and the cement siding on the outside. We were probably lucky though since the company that shipped this to us was in Florida and we’re in Georgia. Our pipes were originally 16 ft. long and we cut them down to about 11 ft. How To Install Pioneer 12000 BTU 230 Volts Ductless Mini Split. We did the copper ones first (as shown), then pulled the black electric cable and drain hose later. At minimum, you’ll need things like: eval(ez_write_tag([[300,250],'homedetoxing_com-box-4','ezslot_0',152,'0','0'])); Before we go into the install, you’ll need to decide what size mini split you need to buy. We’ll be updating again as we get into summer and winter. Even though the unit size we selected could probably work in a space that’s about as twice the square footage of ours, this is probably most realistic for a normal, well-insulated area only.eval(ez_write_tag([[336,280],'homedetoxing_com-banner-1','ezslot_15',153,'0','0'])); For reference, coming to this garage workspace in the early morning during the winter usually means it’s 30°F to 45°F outside, while in the summer early evening, it’s 90°F to 98°F usually. It starts at around 13 minutes into the video. Within 15 minutes of use, this unit was cooling just the same as the main air conditioner in the rest of our home. High Seer offers most extensive HVAC product range in the market today at wholesale factory direct prices. Next, we cut and flared the copper pipes. I’m thinking about trying the Pioneer next because it’s a bit less expensive and has a better trouble shooting and install manual. The copper ends came with a flare so I used them. With respect to the vacuum pump process my understanding is the low pressure (blue hose and blue gauge) side gets evacuated. Be sure the connectors labeled 1-2-3 and ground match the inside wall unit. Every install will be a bit different since electrical box locations, walls and other things can change a layout. Ours gave us a range from 20 to 30 Amps. Once we decided where to mount the indoor unit, we unscrewed the center screw of the metal plate on the back of it with a Phillips screwdriver to release the mounting plate. It came with: Our install can be summed up in several stages: For now, you only need to position and install the mounting plate without the indoor unit. Your email address will not be published. The colors weren’t exactly the same, but it was manageable. I have a question about the evacuation process. There was a 17seer but now they are 19seer IE the 19rl Look at the back of the unit for were the line-set and wiring stick out for were the hole will need to be drilled. Disconnect the vacuum hose line after letting in refrigerant. We recently installed a desperately needed air conditioner mini split with a heat pump in our home. It is the only service port on the unit. First, we cut out two holes in the disconnect box and hung it on the exterior wall. The amount of refrigerant would be fine. Now the gauges should show a positive reading. The nameplate on the side of each unit states the maximum current that needs to be followed when buying things like the breaker, disconnect box, and cables. Can you explain the vacuum pump step in a little better detail? We didn’t need anything fancy, so we simply put our unit on four concrete blocks and used the black rubber pads in between that came with the unit. And to finish off this part of the project, we screwed on the pipes to the unit using the nuts, sealant, and two pliers again (as shown before). When disconnecting this will let a small bit of refrigerant out not allowing any air back into the system. Of course, if you have never done any basic construction or electrical wiring be sure to call a professional. As long as it is the indoor wall unit it can be let loose. An 8″ distance to the left seemed to work for us. Senville SENA-12HF/Z (Cheapest Unit For Less Than $800) If you’re looking for the best cost-benefit … Here is one on Amazon I am wondering if there is any special consideration for this when connecting the outside line set? Next, we connected the vacuum pump to the low side (the smaller copper pipe). It is soft and easily bendable. We happened to have a vinyl gutter lying around unused that we cut up lengthwise with our power saw and secured to the wall. There are some tools that will be needed such as a Vacuum Pump and Manifold Gauges. But other than the $40 tool we bought, it took less than 15 minutes to do for the two pipes. Run pipes through the back of the indoor unit to the outdoor unit. The owner of this website, hvachowto.com, is a participant in the Amazon Services LLC Associates Program, Amazon.com.ca, Inc, Amazon EU Associates Programme an affiliate advertising program designed to provide a means for sites to earn commission income (advertising fees) by advertising and linking hvachowto.com to Amazon properties including, but not limited to, Amazon.com, Amazon.ca, Amazon.co.uk, Amazon.de, Amazon.se, Amazon EU Associates Programme, Amazon.it, Amazon.es, Amazon.fr endless.com, myhabit.com, smallparts.com, or amazonwireless.com Amazon.ca, Amazon.co.uk and other sites worldwide. A pad will be needed to set the outside condensing unit. This is from the WYS series of air conditioners and is manufactured by HighSEER. Can you email me please. then call customer service if you have more questions. To extract coolant is easy peasy for a tech as he would have an empty bottle to capture the gas, again using the gauge set to connect the bottle. As far as our temperature test, here’s how it went. Priority Home and Design LLC is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. I installed the 12000 BTU 230 Volt model which the instructions called for a 20 AMP breaker. Depending on how your indoor and outdoor units are configured, you may or may not have to do this as well. I’m installing a 18000btu unit and the the lines coming from the indoor unit have pressure behind The only difference is whether you’ll have a second 110-120V line or a neutral wire.   We bought our mini split system from Amazon from this seller. The instructions will also show the location and size of the hole needed through the wall. If the outside location already has concrete it can simply be set on it. Update: Since this video, I have learned a lot. Position and install mounting plate for indoor unit. What pressure (and temperature) should the lines be when testing heat and cool mode? I bent the tubing by hand. Solid core wire has been known to cause more issues. To sum up, I recommend only famous and reliable ones. How To Install Pioneer 12000 BTU 230 Volts Ductless Mini Split. Budget 410a Manifold Gauges on Amazon Learn how your comment data is processed. Do-It-Yourself Mini Split air conditioners have become very popular since they are a good alternative to high-cost HVAC installations. Will I need to cut and flare my pipes too? Thanks for the great how to article. We fed one end of the black signal wire towards the terminal block – the other end was outside. These units come already charged with R410a refrigerant, but the answer to this question will depend on how well your own unit is cooling. Feed the line set and wiring out the hole and set the unit on the mounting bracket. The manufacturer recommends having this much free wall space around the indoor unit: You can go more on the left, right, and top if you wish. The last thing to do in this step was to hang the inside unit. I think 20amp needs 12g wire Some other basic tools will also be needed such as a drill, screwdrivers, and wrenches. In the next few steps, we knew we needed to install a hole for the piping on the left based on our configuration, so we wanted to be generous here to avoid our piping from bending too much. ft. West-facing garage in Georgia that’s used as an all-day workspace. Next, we pulled the piping and electrical cable through the hole. Installing the Pioneer Ductless Mini Split was not that difficult and falls into a handy person Do-it-yourself category. Let it sit for at least 20-30 minutes or more and be sure it holds a negative pressure. They will need a few turns for the valve to come fully open. So far, we’re happy. One problem I had was the wire color codes were not exactly the same as the wiring harness sent to me. Small pads are low-cost items that can be purchased and what I use for example this one on Amazon. Always make sure to consult with a qualified and licensed electrician and HVAC technician. If you use anything but the 16 foot lineset I would get a tech in to help you with that final part. What’s Included with the Mini Split System, We bought our mini split system from Amazon from this seller, The Klein Tools meter we used can be found here. Next, we drilled a hole 8″ away from the mounting plate, using a stud finder to make sure we’re drilling in between studs this time. through 36,000 BTU/h.. Inverter+ WAS Series … Thank you again. As an example, I’m a Toyota guy, and when I buy a Toyota I know what to expect, quality. 3. Once you are satisfied that the pressure is holding steady and there are no leaks pioneer instructs you to open the refrigerant line a quarter turn for 5 seconds then close the refrigerant. 85. I am getting ready to install one of these 1200BTU WYS012GMFI19RL You did not state the model # of yours. We also connected the copper pipes using sealant and tightened everything up with two pliers. In our case, the hole was on the left side of the unit. We bought the 24,000 BTU size (WYS024), which is what will be shown in this post. What kind of refrigerant did you use? It hangs from the screws in the top first, then is supposed to click into place at the bottom once it gets flush with the wall. The mounting bracket is on the back of the inside unit held in place with a Philips screw. It held under the zero to -30 Hg range the entire time, so the pressure held just fine as is. High Seer HVAC, Mini Split, Multi Split, Pioneer, Heat Pump, Air Conditioner, Inverter. ( “Additional refrigerant/Liquid side 1/4″/per additional feet:0.16oz/ft”). We had a minor question we asked the manufacturer on Amazon, and within less than an hour, we had a response. Once hand tight use a wrench to tighten them up and get a good seal. This was not much of a problem as the inside and outside units are labeled 1-2-3 and ground. The connectors are located under the front panel under a pull out on the right side. Then, it’s as simple as tightening the handle on the tool until the tube is flared. If your don’t shorten the lines, you won’t need to re-flare them. Do the electric work – install the electric breaker, disconnect box, and run the wiring between. I think the directions say when you release the refrigerant just do a little then check to make sure it hold.   Flaring was fairly simple. Also, remember that the piping length and drop is proportional to the BTU capacity on your unit and has its limitations (check page 25 of your installation manual). It made working in the garage just “bearable”, but nothing more than that. Anyhow your breaker is over sized should be 15amp. Now that one side of the copper piping and drain hose were out the exterior wall, the other ends needed to be fed through this knockout panel so that they could connect in the back of the inside unit. I also soaped the connections. Required fields are marked *. Thanks Earl. My question is I have a 12000 BTU 230V Pioneer mini split with a 25′ line set and I think I will be using just about every foot of it. Most HVAC companies will install a disconnect box which simply breaks the flow of electricity when work is needed on the unit. That is their brand and they have earned the recognition that comes with it. PIONEER Air Conditioner Ductless Mini Split System Charging Vacuum Port Adapter, Converts New R410a Style 5/16 SAE Service Ports to Accept Older 1/4 SAE Gauge Hoses. the reason that I ask is that in researching I thought that I had read elsewhere that you needed an additional ounce for each additional 6′. View and Download Pioneer Inverter+ WAS Series installation manual online. Most local codes require 14 gauge wire, so using something smaller will not pass inspection in many areas. (21 pages) Air Conditioner Pioneer Inverter+ WAS Series Installation Manual We cut our copper pipes down from 16 ft to about 11 ft for two reasons. Thx for the reply. After another hour of maintaining the pressure, we took the caps off the king valves on both pipes using a folding Allen key. This site uses Akismet to reduce spam. Two, we needed to cut the pipe because of the way our indoor and outdoor units were positioned. It does flash the temperature the unit is set on, can you turn the temperature down to 68-69 degrees and see if it comes on? Only the garage door was well-insulated, with an attic above it. The blue side is for low pressure. The piping on the back of the indoor unit could’ve been configured better and so could the colors on the electric wiring. The outdoor unit must be installed based on where the pipes are, but there must be a bit of room since the pipes are stiff and shouldn’t bend too much. Can’t power it off, turn it down or up with it. If there is no pad one can be bought or a small cement pad can be poured. Next, we cut out a “knockout panel” on the inside unit on the same side where the hole in the wall was. The wire harness will need to be fed in from the back. Two people can carry it using what appear to be handles on the side, in case you’re wondering. We’ll be working with the 230V configuration for our unit. The unit comes as stated pre-charged for the expectation of a 16 foot lineset. For example, here it is hooked to the Red Gauge and the pressure is negative with the dial under the zero marker. Guess they need to update their listing. Hello I tried to turn the unit on and all I’m getting is beeping sound with a blinking number 88. Some are standard, like a timer or energy-efficiency mode. While we were doing this, we readjusted, wrapped, and insulated our pipes and cables at the same time. This site is owned and operated by Priority Home and Design LLC, a limited liability company headquartered in Georgia, USA. How To Install Pioneer … Unit is level on pads now, just want to know if it needs to be secured with expansion bolts, etc.. Its not necessary as they don’t move but guess it couldn’t hurt. In case you need guidance on the color-coding, there is a diagram under the top panel that is lifted up on the top indoor unit. Connect the control wire to your indoor unit. Pioneer Circuits is a small business with a long history of big innovations and highly advanced technological capabilities. There are a few things that need to be done before it can be mounted. There is a Wi-Fi function available, but we didn’t see the need to purchase any extra accessories. The L1 and L2 go the circuit breaker for power. Power on the unit using the remote control. With a number of innovative features that keep noise disruption to a minimum, mini-split … I bought one of these, Pioneer WAS/WYS 9000 but with a 33′ lineset, is the book correct that I need to add 16oz for additional foot, or in this case 17′ x 16oz= 272 ozs , that seems like a awful lot. How close can I get and have it work? We then connected the black and white cables to the breaker we inserted, checked the voltage with a meter, and moved on to work on the indoor unit. Now before I ever make a big purchase I always like to take the time and consider the brand and the company behind the product. View and Download Pioneer Inverter+ WAS Series owner's manual online. So for example if a unit comes with 16 feet of line set and you only need 10 feet you can avoid flaring by coiling up the excess. Using manifold gauges and a pump hook up to the low-side port. The indoor unit looks stylish and isn’t an eye sore. We waited 45 minutes in between each step. Ideal-Air 728184 2 x 16 x 36 Cement Equipment Pad Note – you have to be licensed to work with R410A refrigerant, which we are. The wire should be stranded, not solid core. The unit was cooling just fine. Make su… https://removeandreplace.com/2017/06/19/pioneer-air-conditioner-mini-split-error-codes-and-troubleshooting-guide/. Adding coolant is pretty easy, albeit maybe expensive for a single job. There is no need to add or take away from the refrigerant just because you happen to shorten or extend the lines, unless your lines will need to be at least 25 feet long overall. 8 Reason a Furnace Will Not Work Fall and Winter Maintenance Tips, Our Picks for the Best Mini Split Air Conditioner. No there is no set distance, technically the amount of refrigerant that comes in the unit accounts for the 16 foot line-set, but this should not make much difference. The Klein Tools meter we used can be found here. We also cut the sheetrock and ran a cable between the fuse box and disconnect box. The plastic piece that goes in between arrived slightly damaged as you can see, but it wasn’t a big deal for us. Any ideas as to what it could be? The piping connections are made directly in the back of the unit, in the center. We installed the unit in mid-April. Overall, this was a good buy. I have a question about my connection’s? They may also have different size and length connecting pipes, so make sure to adjust to your specific installation manual as you do your own install.eval(ez_write_tag([[250,250],'homedetoxing_com-medrectangle-4','ezslot_3',151,'0','0']));eval(ez_write_tag([[250,250],'homedetoxing_com-medrectangle-4','ezslot_4',151,'0','1'])); If you have most of the tools on hand already, you’ll need to dish out at least $50 extra on top of the A/C.

Butterfly Dream Netflix, Kenmore Parts Stove, Bistro Table With Umbrella Hole, Canon Pixma Pro 100, Run Command Shortcut, Nasa 2025 War Plan Pdf, Black Limba Table, Dyson V8 Animal Attachments, Rasputin And The Empress, West Broward High School Tv, Morning Glory Pool Yellowstone Video,

You must be logged in to post a comment.